F-01 Tool Disabled (by external control)
F-02 Cycle Delay fault -- trigger was pulled before cycle delay timer expired
F-03 Tool Locked by Smart Socket Function -- user needs to select the correct socket at the PCM
F-04 SPI EEPROM EOR write failure
F-05 SPI EEPROM EOR read failure
1-FF USB enumeration fault
2-<Alarm ID> PM Alarm Time Fault for corresponding Alarm ID normally configured by the user
3-<Alarm ID> PM Alarm Cycle Fault for corresponding Alarm ID normally configured by the user
A-10 Motor controller communication timeout
A-55 A display software version update was detected
A-AA The display memory was re-initialized to factory defaults
A-11 Firmware mismatch with Display Version 2.1.2.0. Update MCE Firmware to Version 1.1.1.0 (this is embedded in ICS 6.2.1.0)
B-01 Failure to update Motor Controller Software
B-50 Duplicate Tool Location ID detected
B-80 No RF Network Detected after 20 seconds
B-85 RF ACK Timeout (we did not get a serial ACK messages from the transceiver)
B-E1 RF Transmit NAK – “Channel Access Failure”
B-E5 RF Transmit NAK – “Frame Too Long”
B-E9 RF Transmit NAK – “No ACK Received”
B-F0 Bad MCE Checksum
B-F1 Bad Radio Checksum
B-F2 Bad Display Checksum
C-01 Configuration ID value is 0 or greater than 8
C-02 Number of configuration steps is greater than 8
C-03 Current Step ID is greater than the current number of steps
C-04 Total Gang is greater than 8
C-05 Current Gang count is greater than Total Gang
C-06 Current Torque High Limit is greater than the Tool’s maximum Torque value (Tool’s max torque
value is configured in the Factory Set Points) OR Current Torque High Limit is less than 0
C-07 Current Torque Low Limit is greater than the Tool’s maximum Torque value OR
Current Torque Low Limit is less than 0
C-08 Current Torque High Limit is less than Current Torque Low Limit
C-09 Current Torque Low Limit is greater than Current Torque High Limit (Fault code to be removed)
C-0A Current Angle High Limit is greater than the Tool’s maximum Angle value (to be set to 9999)
C-0B Current Angle Low Limit is greater than the Tool’s maximum Angle value (to be set to 9999)
C-0C Current Angle High Limit is less than Current Angle Low Limit
C-0D Current Angle Low Limit is greater than Current Angle High Limit (Fault code to be removed)
C-0E Tool configuration step is a Torque target and the target value is outside the torque high and low
limits
C-0F Tool configuration step is an Angle target and the target value is outside the angle high and low
limits
C-10 Tool configuration step is not set for either Angle or Torque
C-11 Current Threshold value is greater than the maximum tool torque OR
Current Threshold value is less than 0
C-12 Current Free Speed is greater than maximum motor speed
C-13 Current Shiftdown Speed is greater than maximum motor speed
C-14 Current display unit value is unsupported
C-15 Current Shiftdown Point if above target or above Target (for torque strategy) or above tool's torque
limit (for angle strategy).
C-16 Number of configuration steps is set to 0
C-17 Config programmed partially i.e., does not match with no. of steps
C-18 Current Target exceeds value 9999.9 (i.e., 9999 is the max valued that can be displayed on the
OLED and decimal value .9 is not displayed in this case)
C-77 Invalid Time Stamp value in set time message.
E-00 Using MC Software 1.0.1.2, Battery Fault
E-01 Using MC Software 1.0.1.2, Invalid Hall State
E-02 Using MC Software 1.0.1.2, I2T Fault
E-03 Using MC Software 1.0.1.2, Motor Stall
E-04 Using MC Software 1.0.1.2, Over Current
E-05 Using MC Software 1.0.1.2, Over Temperature
E-06 Using MC Software 1.0.1.2, Current Offset
E-07 Using MC Software 1.0.1.2, Shunt Cal
E-08 Using MC Software 1.0.1.2, Torque Offset Fault
E-09 Using MC Software 1.0.1.2, Transducer Fault
E-0A Using MC Software 1.0.1.2, Step Execution Timeout
E-0B Using MC Software 1.0.1.2, Configuration Execution Timeout
E-0C Using MC Software 1.0.1.2, Over Torque Limit
E-0D Using MC Software 1.0.1.2, Over Angle Limit
E-0E Using MC Software 1.0.1.2, Current Plausibility High
E-0F Using MC Software 1.0.1.2, Under Torque
E-10 Using MC Software 1.0.1.2, Under Angle
E-11 Using MC Software 1.0.1.2, Current Plausibility Low
E-12 Using MC Software 1.0.1.2, Early trigger Release
E-13 Using MC Software 1.0.1.2, Motor Controller Watchdog Reset
E-14 Using MC Software 1.0.1.2, Motor Controller Stop Timeout
E-15 Using MC Software 1.0.1.2, Motor Controller to Display EOR message failure
E-18 Using MC Software 1.0.4.2, Motor Controller did not run all steps (mainly affects Prevailing Torque)
E-1B Using MC Software 1.0.1.2, Battery Cell Fault (detected by Motor Controller)
E-1C Using MC Software 1.0.1.2, Low Battery Fault (detected by Motor Controller)
E-1D Using MC Software 1.0.1.2, Critical Battery Fault (detected by Motor Controller)
E-1E Using MC Software 1.0.1.2, Motor Controller is shutting down
E-1F Using MC Software 1.0.1.2, Wakeup Code received (but not expected)
E-20 Invalid EOR, Thresholds violation
E-81 The configuration ID in the Motor controller's EOR did not match the currently selected
configuration
Tool Event Log codes:
10-01 Configuration Page Update from Communication interface (USB or Wireless)
10-02 Tool Locked by Communication Interface (USB or Wireless)
10-03 Tool disabled by Communication Interface (USB or Wireless)
10-04 Configuration Selected by Communication Interface (USB or Wireless)
10-05 Gang Advanced by Communication Interface (USB or Wireless)
10-06 Gang reset by Communication Interface (USB or Wireless)
10-07 Configuration advanced by Communication Interface (USB or Wireless)
10-08 Configuration Reset by Communication Interface (USB or Wireless)
10-09 SPI Memory erased by Communication Interface (USB or Wireless)
10-0A Tool Reset by Communication Interface (USB or Wireless)
10-0B Factory calibrations restored by Communication Interface (USB or Wireless)
10-0C Cycle log cleared by Communication Interface (USB or Wireless)
10-0D Event log cleared by Communication Interface (USB or Wireless)
10-AA Time updated by Communication Interface (USB or Wireless)
20-01 Complete Tool memory reset to defaults
20-02 Tool reset configuration to Defaults
30-01 PIN reset
30-02 POR/PDR reset
30-03 Software Reset
30-04 Independent Watchdog reset
30-05 Window watchdog reset
30-06 Low-Power reset flag
EE-E0 RF Protocol Error -- RF Message Packet too small
EE-E1 RF Protocol Error -- RF Packet too long
EE-F0 MC Protocol Error -- Invalid Image Checksum
EE-F1 RF Protocol Error -- Invalid Image Checksum
EE-F2 DIS Protocol Error -- Invalid Image Checksum